Boso ABI-system 100 Service Manual

Browse online or download Service Manual for Measuring, testing & control Boso ABI-system 100. boso ABI-system 100 Technical data [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
User instructions for the ABI-system 100
0124
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1

User instructions for the ABI-system 1000124

Page 2 - TM, Windows® 7

10Assignment of the cuffs to the extremities.:Check the correct assignment of the cuffs to the extremities by seperate measure-ments of left arm, righ

Page 3

11Measurement tab:Performed measurements can be viewed in the “Measurements” tab.If several measurements have already been carried out, select the des

Page 4

12Click on one of the oscillation profiles to enlarge the view of the selected profile.The “Pulse level over time” tab shows the oscillation curve ove

Page 5

13Preparing for a measurementThe measurement must be performed on a patient who is lying down in order ensure equal blood pressure among all limbs.The

Page 6

14Taking a measurementIn order to add a new patient in the ABI software, select the “New” button in the “Patient” tab. “Name” and “Patient no.” are ob

Page 7

15Systole (mmHg)Diastole (mmHg)The decreasing cuff pressure will be displayed during the measuring phase. By this time (at the latest) all four limbs

Page 8

16If all of the values were correctly displayed after carrying out the second set of measurements, click the button “Save measurement” and then “Back”

Page 9

17The times above the measurement value columns indicate the time of measurement (1st and 2nd measurement).Cancelling a measurementA measurement can b

Page 10

18Technical dataMeasurement method: oscillometricMeasurement range: 40 – 240 mmHgCuff pressure: 0 – 300 mmHgDisplay: LCDOperating conditions:Ambient t

Page 11

19Technical testing procedureA) Function testingFunction testing of the device can only be performed on human subjects or using a suitable simulator.B

Page 12

2User instructions for the ABI-system 1001 ABI-system 1002 CA04 cuffs (for upper arms)2 CL04 cuffs (for legs)1 ABI-system 100 software 1 USB cab

Page 13

20Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into ser-vice according the EMC information p

Page 14

21150 kHz to 80 MHzd = 1,2 P0,120,381,23,812Guidance and manufacturer’s declaration – electromagnetic immunityThe boso unit is intended for use in

Page 16

23Your notes:

Page 17

BOSCH + SOHN GmbH u. Co. KGBahnhofstraße64•72417Jungingen•GermanyPhone:+49(7477)9275-0•Fax:+49(7477)1021Internet:www.boso.de•e-Ma

Page 18

3Explanation of symbols and user controlsSTART keyPressthiskeytostartanABImeasurement.All4cuffswillbeinated.STOP keyPress this key to

Page 19

4Read the user instructions!Explanation of symbols usedClass II deviceProtection level against electric shock: Type BFUSB 2.0ConnectionThe CE symbol i

Page 20

5Introductory informationYour boso ABI-system 100 is an innovation on the market for blood pressure mea-surement. It represents an easy way to determi

Page 21

6ABIThe systolic blood pressure values of a person’s arms and legs need to be mea-sured in order to determine the ABI value. The blood pressure measur

Page 22 - Your notes:

7Installing the network versionFirstly you need to install the Firebird database server locally on the server by clicking the button “Installiere Fire

Page 23

8Installing the USB connection cable• Connect the USB connection cable to a free USB port on your PC.• WINDOWS automatically detects the USB-cableData

Page 24 - BOSCH + SOHN GmbH u. Co. KG

9Entering doctor’s data:The personal data of the doctor in charge can be entered in the “Doctor” tab which is then used as the basis for the printout